Used PERKIN ELMER Victor X5 Microplate Reader 出售 - DOTmed 目录 #3042031:

Clean Sweep Live Auction on Wed. Mar. 11th. Click to view the full inventory

PERKIN ELMER Victor X5 Microplate Reader for sale
PERKIN ELMER Victor X5 Microplate Reader for sale

出售 PERKIN ELMER Victor X5 Microplate Reader

  • Asking Price :$5,995.00 USD
  • Condition : Used - Good
  • Est. Shipping(US) : $300.00 USD
  • Qty. Available : 1
  • In Stock : Yes
  • Date : February 24, 2020
  • credit-card
  • credit-card
  • credit-card
  • credit-card

Item Description

Seller assumes all responsibility for this listing.

Listing: #3042031

  • Condition: Used - Good
  • Brand: PERKIN ELMER
  • Type: Microplate Reader
  • Model: Victor X5
  • MPN: 14813
  • Warranty: 30 Days Warranty
Here is a Perkin Elmer VICTOR X5 2030 Multilabel HTS Microplate Reader

P/N 2030-0050

Predecessor to:
Current model.

Condition:
This Perkin Elmer VICTOR X5 2030 Multilabel HTS Microplate Reader is in good working order.

Please see the exact video and photos below.

Testing we performed:
The Perkin Elmer VICTOR X5 2030 Multilabel HTS Microplate Reader passed all tests and was found to be fully functional:
Tested communication with software: PASSED
Tested photometry "Absorbance": PASSED
Tested fluorometry: PASSED
Tested luminometry: PASSED
Tested shaking: PASSED
Tested temperature control: PASSED

Using Perkin Elmer Multi label Test Plate and our Rainbow Test Plate this Perkin Elmer VICTOR X5 2030 Multilabel HTS Microplate Reader has been shown to be working.
Our testing confirms operation of the electronics, optics (Light source, fiber optics, mirrors, filters and detectors), stage, stacker, and temperature control.
Due to this testing you can Perkin Elmer VICTOR X5 2030 Multilabel HTS Microplate Reader with confidence knowing it is ready to go.

System consists of:
Perkin Elmer Victor X5 2030 Multilabel HTS Microplate Reader 2030-0050
Rotatable filter wheel A, provided with 8 filter positions with the following filters:
1. 405NM 8C109
2. F0829A PA540
3. F0826A P492
4. D480/30 X 209635
5. F0824A F485
6. F0807A F355
7. F0843A P340-25
8. F0719A F531
Filter Slide A with the following filters:
1. F0824A T616
2. F0817A T642
3. 595AF60 83375
4. D535/40 209322
5. F0825A F535
6. 460NM 8H018
7. 700CFSP 74804
8. 665NM 8B046

Desktop PC running Windows 10 with PerkinElmer 2030 Manager software ver4.0 (with monitor, keyboard, mouse)
Communication and power cables.

Configuration and Setup:
Light sources
Continuous light source for fluorometric and photometric measurements:
1. Tungsten-halogen lamp, 75W, lifetime > 300h, Spectral range 320-1000nm
2. Rotatable filter wheel A, provided with 8 filter positions (D15mm). Standard high quality interference filters 405nm, 450nm, 490nm, 355nm (not for fluorescence polarization), 485nm. Changeable rotatable filter wheel B, provided with 4 filter positions (D25.4mm).
Optional flash light source for TR-fluorometric measurements:
1. UV xenon flash tube, L4642 or equivalent, spectral range 230-400nm
2. Filter slide, provided with 3 filter positions (D22.4mm). Filters 340, 260 and 280nm

Detection units
Photometry: photo diode, photometric range 320-1000nm
Fluorometry (Top and Bottom), luminometry and optional TR-fluorometry:
Photomultiplier tube, w/optional R4632
Luminescence Detection (96-well plate): Lower limit of detection (LLD) - total flux of 20,000 photons/s (standard PMT), 100,000 photons/s (red-sensitive PMT)
ALP 1 amol/well with AMPPD substrate
Flash luminescence 80 amol/well ATP
Glow luminescence 0.9 pg/well using briteliteT

Fluorescence Polarization (384-well black plate):
Fluorescein 1nM, 40uL
Standard deviation <5mP

Absorbance Detection (96-well plate):
Measuring range @405nm 0-4 A
Accuracy @405nm <2% (or 0.01 A) within 0-2 A
Precision @405nm <0.5% (or 0.01 A) within 0-2 A

TR-Fluorescence Detection (200uL, 96-well plate):
Europium <6 amol/well, 30 fM
Linearity >5 decades
Crosstalk <0.01%
Terbium <5 amol/well, 25 fM
Samarium <50 amol/well, 250 fM
Dysprosium <150 amol/well, 750 fM

Fluorescence Detection (200uL, 96-well black plate):
Fluorescein <2 fmol/well, 10 pM
Linearity >5 decades
Crosstalk <0.01%
Umbelliferone <200 fmol/well, 1 nM
Rhodamine <100 fmol/well, 0.5 nM

Video Description:
First we pan to monitor to see software running. Then we observe the Perkin VICTOR X5 2030 Multilabel HTS Microplate Reader operating.
After that we see results of reading at the monitor. And after a final look at the Perkin VICTOR X5 2030 Multilabel HTS Microplate Reader the video ends.

TO VIEW ADDITIONAL PHOTOS, VIDEOS AND VERY DETAILED INFORMATION SUCH AS TEST STEPS PERFORMED, CONFIGURATION, ETC., PLEASE VISIT OUR WEB SITE. TO GET THERE PLEASE CLICK ON "WEBSTORE" TO YOUR RIGHT AND YOU WILL SEE LINK TO OUR SITE IN THE MIDDLE OF THE SCREEN. THEN USE LAST 5 DIGITS OF MPN NUMBER IN THE SEARCH FIELD TO LOCATE YOUR ITEM.

DO NOT HESITATE TO CALL US OR EMAIL US WITH ANY QUESTIONS YOU MIGHT HAVE.

ALL OF OUR ITEMS ARE AVAILABLE FOR INSPECTION AT OUR FACILITY.

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Boston Industries, Inc.
Mark Kuznets This user has not been rated
Shop with confidence
[x]
Chat with the Owner

We're Offline

Send message to seller