For Sale PHILIPS 55177 Respironics BiPAP A30 Ventilator

  • Condition : Used - Good
  • Weight : 2.00 Kg
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 06, 2024
  • Listing # : 3254363
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #3254363

  • Condition: Used - Good
  • Brand: PHILIPS
  • Type: Ventilator
  • Model: 55177 Respironics BiPAP A30
  • MPN: 55177
  • Amperage:  5,0 A
  • Depth: 5 inches
  • Height: 8 inches
  • Width: 9 inches
  • Dual Mode: No
  • Inspiration Pressure: 4 bis 30 cm H₂O
  • Peep Pressure: 4 bis 25 cm H₂O
Deutsch:
BiPAP A30 specifications

Gewicht: 2,1 kg (mit Netzteil)
Größe: 21,6 cm x 19 cm x 11,5 cm (B x L x H)
Gleichstromquelle: 12 V Gleichspannung, 5,0 A (externer Akku), 24 V Gleichspannung, 4,2 A (Netzteil)

Beatmungsmodi: CPAP, S, S/T, PC, T
Hybride Beatmung: AVAPS (Average Volume Assured Pressure Support, Druckunterstützung mit gesichertem Durchschnittsvolumen)

IPAP: 4 bis 30 cm H₂O
EPAP: 4 bis 25 cm H₂O
AVAPS-Frequenz: 0,5 bis 5 cmH2O/min
Batterie-Notstromsystem: 11 Stunden bei IPAP 15/EPAP 4 cm H2O und 12 Atemzügen/min
Soll-Tidalvolumen (bei aktivierter AVAPS): 200 bis 1500 ml

Inspirationszeit: 0,5 bis 3 Sekunden
Anstiegszeit: 1 (100 ms) bis 6 (600 ms)
Atemfrequenz: 0 bis 40

Verbindungen für Polygraph und Polysomnographie: Direkte Verbindung mit Alice PDx und Alice6 PSGs, AOM für die Verbindung mit den meisten PSG-Systemen
Auslösung und Zyklussteuerung: Digital Auto-TRAK Algorithmus

Betriebsgeräusch: 30 dBA bei 10 cm H2O
Befeuchtung: System One Feuchtigkeitsregelung und „Dry Box“-Technologie

Alarme: Patientendiskonnektion, Apnoe, niedriges Atemminutenvolumen, niedriges Tidalvolumen (nur bei AVAPS), hohe Atemfrequenz

Patientenmonitoring: Druck, Tidalvolumen, Atemminutenvolumen, Atemfrequenz, Leckage, I:E-Verhältnis
Datenmanagement: EncorePro 2 und DirectView Software Mit Oxymetriemodul kompatibel, erweiterte Erkennung von residualen respiratorischen Ereignissen (Apnoe-Hypopnoe-Index, obstruktive Apnoe, zentrale Apnoe, Hypopnoe, periodische Atmung, RERA, große Lecks und Schnarchen)

Fernbedienung
Kompatibel mit PC Direct

Englisch:
BiPAP A30 specifications

Weight: 2. 1 kg (with power supply)
Size: 21. 6 cm x 19 cm x 11. 5 cm (W x W x H)
DC source: 12 V DC voltage, 5. 0 A (external battery), 24 V DC voltage, 4. 2 A (power supply)

Modes of Vespiratory: CPAP, S, S/T, PC, T
Hybrid respiration: AVAPS (Average Volume Assured Pressure Support)

IPAP: 4 to 30 cm H2O
EPAP: 4 to 25 cm H2O
AVAPS frequency: 0. 5 to 5 cmH2O/ min
Battery backup system: 11 hours at IPAP 15/EPAP 4 cm H2O and 12 breaths /min
Target tidal volume (if AVAPS is activated): 200 to 1500 ml

Inspiration time: 0. 5 to 3 seconds
Ascent time: 1 (100 ms) to 6 (600 ms)
Respiratory frequency: 0 to 40

Compounds for polygraph and polysomnography: Direct connection to Alice PDx and Alice6 PSGs, AOM for connection to most PSG systems
Intrusion and cycle control: Digital Auto-TRAK Algorithm

Operating noise: 30 dBA at 10 cm H2O
Humidification: System One humidity control and “dry box” technology

Alerts: patient’s disconnection, apnea, low respiration minute volume, low tidal volume (AVAPS only), high respiration rate

Patient monitoring: pressure, tidal volume, respiration minute volume, respiration rate, leakage, I:E ratio
Data Management: EncorePro 2 and DirectView Software Compatible with oximetry module, advanced detection of residual respiratory events (apnea-hypopnea index, obstructive apnea, central apnea, hypopnea, periodic respiration, RERA, large leaks and snoring)