Over 1850 Total Lots Up For Auction at Six Locations - MA 04/30, NJ Cleansweep 05/02, TX 05/03, TX 05/06, NJ 05/08, WA 05/09

spacer
Listing 4682910 Listing 4682910 Listing 4682910 Listing 4682910 Listing 4682910 Listing 4682910
Listing 4682910 Listing 4682910 Listing 4682910 Listing 4682910 Listing 4682910 Listing 4682910

For Sale MIDMARK 623-008 Exam Room Suite

  • Condition : Used - Good
  • Weight : 385.00 Lbs
  • Qty. Available : 1
  • In Stock : Yes
  • Date : April 27, 2024
  • Listing # : 4682910
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4682910

  • Condition: Used - Good
  • Brand: MIDMARK
  • Type: Exam Room Suite
  • Model: 623-008
  • MPN: 623-008
  • Depth: 35 inches
  • Height: 40 inches
  • Width: 62 inches


Product Functionality

Technician Notes: USED but in Good Condition. MIDMARK, MODEL: 623-008, S/N: V707953, INPUT: 115VAC @ 13.5A, 50/60Hz., FOOT CONTROL VOLTAGE: 4VAC, SELV(SAFETY EXTRA LOW VOLTAGE), ACTUATOR DUTY CYCLE: INTERMITTENT (DOMESTIC: 30secs ON / 5mins OFF), DUAL RECEPTACLE / DRAWER HEATER / UPH HEATER: CONTINUOUS OPERATION. IP RATING: IPXO [foot control only:IPX1], TABLE SPEEDS: BASE:14-26secs, BACK:15-20secs. DIMENSIONS: TABLE WEIGHT (w/ upholstery): APPROX. 325LBS. 400lbs MAX PATIENT CAPACITY, MAX HEIGHT (extended): 37inches +/-0.5" (home height: 20"+/-0.5"), MAXIMUM LENGTH (EXTENDED): 74" (home length: 56.26"), WIDTH: 30.5", HORIZONTAL SLOPE: 0°-80°+/-5°. DEFECTS: MINOR DISCOLORATION, REAR HANDHELD CONTROL w/ CALL BUTTON DOES NOT WORK. RUBBER STOPPER FOR LIMIT SWITCH IS DAMAGED (LIMIT BSWITCH FULLY FUNCTIONAL, FRONT DRAWER LEFT SLIDE IS LOOSE.
Items Included: MIDMARK 623-008 EXAMINATION TABLE
Missing Components: Operations Manual, Accessory cables
R2v3 Functionality: 

F4 - Hardware Functional  
All hardware is tested and verified working through manual or software tests
No missing or damaged components or parts
Software not loaded or configured
No hardware defects

Cosmetic Description

Scuffs/Scratches/Marks: some scuffs and scratches
R2v3 Cosmetics: 

C4 - Used Good  
Cosmetic blemishes include minor scratches and/or other surface imperfections from consistent use, but equipment is in good condition overall
Minor wear of labeling may be visible
Small dents and small areas of discoloration may be present from the removal of tags
No damage to latches or hinges, nor any missing parts, panels, bezels, or covers
"""NOTE:- LEGAL DISCLAIMER PURCHASE TERMS
Buyer accepts all responsibility for the electrical safety inspection, testing and calibration when applicable, of a purchased item. Medical and dental items must be inspected for safety by a biomedical technician before being placed into use. The buyer is responsible for ensuring the safety of the item for its intended use. If the item is to be used in conjunction with patient care and/or diagnosis, it is the responsibility of the buyer to get proper certifications or licenses for the use of the item."""

Return Policy

30-day D.O.A. applies if an item arrives in any condition other than what is listed in the description.
Seller Information
Sunnking inc.
(2)
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: