Over 90 Total Lots Up For Auction at One Location - WA 04/08

spacer
Listing 2376131
Listing 2376131

For Sale CABLES AND SENSORS MAX-11 FiO2 Sensor

  • Asking Price :$133.00 USD [convert]
  • Condition : New
  • Weight : 0.25 Lbs
  • Qty. Available : 10
  • Date : March 24, 2024
  • Listing # : 2376131
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #2376131

  • Condition: New
  • Brand: CABLES AND SENSORS
  • Type: Anesthesia Accessories
  • Model: MAX-11
  • MPN: G0-020
  • Depth: 4 inches
  • Height: 6 inches
  • Width: 6 inches
  • Warranty: 6 Months

The Maxtec MAX-11 Oxygen Cell is an FiO2 (Fraction of Inspired Oxygen) cell compatible with a variety of systems and primarily used with anesthesia machines. Check the Specifications section for specific compatibility information.

Warranty:

  • #G0-020 (Maxtec Equivalent): 6 Months - Free of Manufacturing Defects.
  • #R113P10 (Maxtec): 1 Year (Shelf Life).

Note: Can only be shipped within the U.S.

Maxtec MAX-11 Oxygen Cell Specifications
  • #G0-020 (Maxtec Equivalent):
    • Primary OEM: 6803290.
    • Response Time: Less than 12 seconds.
    • Connector Type: Gold plated slip rings.
    • Origin: Germany.
    • Available for Use With:
      • Drager: 6000, Anemone, Babylog 8000, Evita 2, Evita 2 Dura, Evita 4, Fabius, Fabius GS, Narkomed 1A, Narkomed 2, Narkomed 2B, Narkomed 3, Narkomed 4, Narkomed GS, Oxycom 100 D, Oxydig, PM8030, SA2, Savina.
      • Drager - Air-Shields: 8000IC, I-8000.
      • Viamed: R-23V.
  • #R113P10 (Maxtec):
    • Output: 17 +/- 3 mV.
    • Response Time: ≤ 13 seconds.
    • Linearity: Less than 3.0% of full scale.
    • Range of Measurement: 0 to 100%.
    • Drift: Less than or equal to 1% volume O2 per month in air.
    • Expected Lifetime: Greater than 500,000 %O2 hours.
    • Equivalent to:
      • Analytical Industries: PSR 11 915 2.
      • Drager: 6803290, 6850645, Narkomed G5, Evita Family, Babylog, Cato, Fabius Series (including GS).
      • EnviteC: OOM-201.
      • HillRom: PSR-11-915-2.
      • International Technologies: M-02.
      • Invivo: Magnitude.
      • Mercury Medical: 10-103-07.
      • Pacifitech: PT-14A.
      • Teledyne: R-23 #C-611391.
      • Teleflex (Hudson): 5557, V-14.
      • VTI: 101372, 100352, 101372, 100352.
    • Also compatible with the Drager Apollo Anesthesia Machine.
Maxtec MAX-11 Oxygen Cell Configurations
  • #G0-020: Maxtec Equivalent (Cables and Sensors Brand).
  • #R113P10: Genuine (Maxtec Brand).
Seller Information
MFI Medical
Shop with confidence
Citi Capital Groupspacer